/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q24P In which technique, iodimetry or... [FREE SOLUTION] | 91影视

91影视

In which technique, iodimetry or iodometry, is starch indicator not added until just before the end point? Why?

Short Answer

Expert verified

Starch is added just before the end point in iodometry technique when the I3-starts to fade. It is not added at the beginning of the technique because some of I2 would stay bounded to starch and the end point would not be detected right.

Step by step solution

01

Definition of Iodometry.

  • Iodometry, regularly called iodometric titration, is a redox titration approach wherein the emergence or disappearance of essential iodine determines the cease point.
  • In iodometry iodide is added to a solution of an oxidizing agent. The iodide is oxidized to iodine. The iodine is titrated with sodium thiosulfate for quantitative analysis.
  • In iodimetry, the titration is done with iodine solution.
02

Determine the technique that used starch indicator not added until the end point.

  • Starch is added just before the end point in iodometry when the I3-starts to fade.
  • It is not added at the beginning of the technique because some of would stay bounded to starch and the end point would not be detected right.
  • A starch solution is used as an indicator in an iodometric titration because it can absorb the I3that is emitted.
  • When titrated with standardised thiosulfate solution, this absorption causes the solution's colour to change from deep blue to pale yellow.
  • This represents the titration's termination point.
  • Iodometry is a technique for determining the quantity of oxidising chemicals in water samples, such as oxygen saturation in ecological research or active chlorine in pool water analysis.

Hence, starch is added before the end point in iodometry technique.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91影视!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

A titration of 50.0 mLof unknown Fe2+with 0.100MCeat 25C , monitored with Pt and calomel electrodes, gave data in the table. Prepare a Gran plot and decide which data lie on a straight line. Find the x-intercept of this line, which is the equivalence volume. Calculate the molarity of Fe2+in the unknown.

A titration of\(50.0\;mL\)of unknown\(F{e^{2 + }}\)with\(0.100MCe\)at\(2{5^\circ }C\), monitored with Pt and calomel electrodes, gave data in the table.\(^9\)Prepare a Gran plot and decide which data lie on a straight line. Find the x-intercept of this line, which is the equivalence volume. Calculate the molarity of\(F{e^{2 + }}\)in the unknown.

The Kjeldahl analysis in Section 11-8 is used to measure the nitrogen content of organic compounds, which are digested in boiling sulfuric acid to decompose to ammonia, which, in turn, is distilled into standard acid. The remaining acid is then back-titrated with base. Kjeldahl himself had difficulty in 1880 discerning by lamplight the methyl red indicator end point in the back titration. He could have refrained from working at night, but instead he chose to complete the analysis differently. After distilling the ammonia into standard sulfuric acid, he added a mixture of KIO3and KI to the acid. The liberated iodine was then titrated with thiosulfate, using starch for easy end-point detection even by lamplight. Explain how the thiosulfate titration is related to the nitrogen content of the unknown. Derive a relationship between moles ofNH3 liberated in the digestion and moles of thiosulfate required for titration of iodine.

Would Tris (2,2'-bipyridine)iron be a useful indicator for the titration of Sn2with Mn(EDTA)? (Hint: The potential at the equivalence point must be between the potentials for each redox couple)

Why is iodine almost always used in a solution containing excess l-?

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.