/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q5-11 P Here is a use objective for a ch... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

Here is a use objective for a chemical analysis to be performed at a drinking water purification plant: "Data and results collected quarterly shall will be used to determine whether the concentrations of haloacetates in the treated water demonstrate compliance with the levels set by the Stage 1 Disinfection By-products Rule using Method 552.2"(a specification that sets precision, accuracy, and other requirements).

Which one of the following questions best summarizes the meaning of the use objective?

(i) Are haloacetate concentrations known within specified precision and accuracy?

(ii) Are thehaloacetates detectable in the water?

(iii) Dothehaloacetate concentrations exceed the regulatory limit?

Short Answer

Expert verified

Amongst statements i, ii, and iii, statement iii is the right answer.

Step by step solution

01

Definition of chemical analysis

Chemical analysis is the study of a substance's chemical composition and structure. More broadly, it can be thought of as the collection of all procedures for obtaining precise chemical data.

02

Reason for right answer

Statement 3 is the right answer.

The purpose of the analysis is to check if concentrations do not go beyond the levels set by a definite rule.

03

Reason for wrong answer

Statements 1 and 2 are wrong because the queries about precision, and accuracy, and detectability in water are irrelevant to the data collection


Conclusion

The question above explained how the data and results collected quarterly will be used to determine whether the concentrations of haloacetates in the treated water are in compliance with the statutory levels..

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

(a) From Box 5-3, estimate the minimum expected coefficient of variation,CV(%)

, for interlaboratory results when the analyte concentration is (i) 1 wt % or (ii) 1 part per trillion.

(b) The coefficient of variation within a laboratory is typically~0.5-0.7of the between-laboratory variation. If your class analyzes an unknown containing10wt%NH3, what is the minimum expected coefficient of variation for the class?

Olympic athletes are tested to see if they are using illegal performance-enhancing drugs. Suppose that urine samples are taken and analyzed and the rate of false positive results is 1 %. Suppose also that it is too expensive to refine the method to reduce the rate of false positive results. We do not want to accuse innocent people of using illegal drugs. What can you do to reduce the rate of false accusations even though the test always has a false positive rate of 1 %?

Blind Samples: Interpreting Statistics-- The U.S. Department of Agriculture provided homogenized beef baby food samples to three labs for analysis.4Results from the labs agreed well for protein, fat, zinc, riboflavin, and palmitic acid. Results for iron were questionable: Lab A, 1.59±0.14(13); Lab B, 1.65±0.56 (8); Lab C, 2.68±0.78(3) mg/100 g . Uncertainty is the standard deviation, with the number of replicate analyses in parentheses. Use two separate t tests to compare results from Lab Cwith those from Lab A and Lab B at the 95 % confidence level. Comment on the sensibility of the t test results and offer your own conclusions.

In a murder trial in the 1990 s, the defendant's blood was found at the crime scene. The prosecutor argued that blood was left by the defendant during the crime. The defense argued that police "planted" the defendant's blood from a sample collected later. Blood is normally collected in a vial containing the metal-binding compound EDTA (as an anticoagulant) at a concentration of ~4.5mMafter the vial is filled with blood. At the time of the trial, procedures to measure EDTA in blood were not well established. Even though the amount of EDTA found in the crime-scene blood was orders of magnitude below ~4.5mM

, the jury acquitted the defendant. This trial motivated the development of a new method to measure EDTA in blood.

(a) Precision and accuracy. To measure accuracy and precision of the method, blood was fortified with EDTA to known levels.

Accuracy=100×meanvaluefound-knownvalueknownvaluePrecision=100×standarddeviationmean=coeffcientofvariation

For each of the three spike levels in the table, find the precision and accuracy of the quality control samples.

(b) Detection and quantitation limits. Low concentrations of EDTA near the detection limit gave the following dimensionless instrument readings: 175,104,164,193,131,189,155,133,151, and 176. Ten blanks had a mean reading of 45 - 1 . The slope of the calibration curve is1.75×199M-1. Estimate the signal and concentration detection limits and the lower limit of quantitation for EDTA.

What are the three parts of quality assurance? What questions are asked in each part and what actions are taken in each part?

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.