/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q16P In a murder trial in the 1990 s,... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

In a murder trial in the 1990 s, the defendant's blood was found at the crime scene. The prosecutor argued that blood was left by the defendant during the crime. The defense argued that police "planted" the defendant's blood from a sample collected later. Blood is normally collected in a vial containing the metal-binding compound EDTA (as an anticoagulant) at a concentration of ~4.5mMafter the vial is filled with blood. At the time of the trial, procedures to measure EDTA in blood were not well established. Even though the amount of EDTA found in the crime-scene blood was orders of magnitude below ~4.5mM

, the jury acquitted the defendant. This trial motivated the development of a new method to measure EDTA in blood.

(a) Precision and accuracy. To measure accuracy and precision of the method, blood was fortified with EDTA to known levels.

Accuracy=100×meanvaluefound-knownvalueknownvaluePrecision=100×standarddeviationmean=coeffcientofvariation

For each of the three spike levels in the table, find the precision and accuracy of the quality control samples.

(b) Detection and quantitation limits. Low concentrations of EDTA near the detection limit gave the following dimensionless instrument readings: 175,104,164,193,131,189,155,133,151, and 176. Ten blanks had a mean reading of 45 - 1 . The slope of the calibration curve is1.75×199M-1. Estimate the signal and concentration detection limits and the lower limit of quantitation for EDTA.

Short Answer

Expert verified

(a) The required solution is 22.2ng/mL:localid="1654937944575" precisionis23.8%; accuracy(b)(

(b) 9is6.6%and 88.2ng/mL:precisionis7.8%;accuracyand314ng/mL:precisionis7.8%;accuracyis-3.6%

(c) Signal detection Limit 129.6

Concentration detection limit is4.8×10-8M

Lower detection of quantitationis1.6×10-7M

Step by step solution

01

Definition of precision, accuracy and detection and quantitation limits

  • Precision refers to how closely a set of measurements are related to one another. Even if the results are not close to the right value, precise measurements are extremely reproducible.
  • The degree of similarity between a measurement and its true value is known as accuracy.
  • The lowest concentration of analyte that can be consistently detected and quantified are defined as the limits of detection (LOD) and quantitation (LOQ), respectively.
02

Determine the accuracy and precision for 22.2ng/mL 88.2ng/mL 314ng/mL

(a)

Find the accuracy and precision of the analytical procedure utilised in the first portion of the issue (part a). To do so, we must first calculate the sample mean and standard deviation.

For 22.2ng/mLx=xin=33.3+19.5+20.8+20.8ng/mL5=118.3ngmL5x=23.66ng/mLs=x1-x)n-1=33.3-23.662+19.5-23.662+20.8-23.662+20.8-23.6624ng/mL=31.663ng/mLs=5.626988537ng/mL

Now solve for precision and accuracy once it accounted for the sample mean and standard deviation:

precision=standarddeviationmean×100=5.626988537ng/mL23.66ng/mL×100=23.78270726%precision=23.8%accuracy=meanvalue-knownvalueknownvalue×100=23.66-22.2ng/mL22.2ng/mL×100=6.576576577%accuracy=6.6%

Let's go on to the second spike, 88.2ng/ML. We'll just do the same thing we did with the prior spike: we'll solve for sample mean standard deviation first, then precision and accuracy.

For localid="1654939640907" 88.2ng/mL;

x=xin=83.6+69.0+83.4+100.0+76.4ng/mL5=412.4ng/mL5x=82.48ng/mLs=x1-x2n-1=83.6-82.482+69.0-82.482+83.4-82.482+100.0-82.482+76.4-82.4824ng/mL=131.932ng/mLs=11.48616559ng/mL

Now solve for precision and accuracy by moving on to the following step:

precision=standarddeviationmean×100=11.48616559ng/mL82.48ng/mL×100=13.926200096%precision=13.9%accuracy=meanvalue-knownvalueknownvalue×100=11.48616559-88.2ng/mL88.2ng/mL×100=6.48526077%accuracy=6.5%

For the final sub-part of letter (a), we simply solve for the sample mean and standard deviation first, followed by precision and accuracy.

For 314ng/mL

x=xin=322+305+282+329+276ng/mL5=1514ng/mL5x=302.8ng/mLs=ix1-xzn-1=322-308.22+305-308.22+282-308.22+329-308.22+276-308.224ng/mL=552.7ng/mLs=23.50957252ng/mL

Precision and accuracy in problem solving:

precision=standarddeviationmean×100=2350957272ng/mL302.8ng/mL×100=7.76405957272%precision=7.8%accuracy=meanvalue-knownvalueknownvalue×100=302.8-314ng/mL314ng/mL×100=3.566878981%accuracy=3.6%

03

Determine the single dectection limit, concertation dectection limit and lower limit of quantitation

(b)

Recall that we are given the following for part b:

yhlank=45×0m=1.75×109M-1

10 instrumental readings: 175, 104, 164, 193, 131, 189, 155, 133, 151, and

Before we can solve the required— single detection limit, concentration detection limit, and lower limit of quantitation— we must compute mean and standard deviation, as we did in the previous part.

How to calculate the sample mean and standard deviation:

x=xin=175+104+164+193+131+189+155+133+151+1765=157110x=157.1s=iix1-xzn-1=175-157.12+104-157.12+L151-157.12+176-157.129=794.9888889s=28.2

Find the required values now that we have obtained the values for the sample mean and standard deviation. After we've written down the formulas, it may apply them to the given and computed values.

signaldetectionlimit=yblank+3s=45.0+3×28.2=45.0+84.6signaldetectionlimit=129.6

concentrationdetectionlimit=3sm=328.21.75×109M-1=84.61.75×109M-1=4.834285714×10-8Mconcentrationdetectionlimit=4.8×10-8M

lowerlimitofquantitation=10sm=1028.21.75×109M=282.01.75×109M-1=1.611428571×10-7M

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

What is the difference between an instrument detection limit and a method detection limit? What is the difference between robustness and intermediate precision?

Internal standard graph -- Data are shown below for chromatographic analysis of naphthalene (C10H8), using deuterated naphthalene (C10D8, in which D is the isotope 2H) as an internal standard. The two compounds emerge from the column at almost identical times and are measured by a mass spectrometer.

(a) Using a spreadsheet such asFigure 4-15, prepare a graph of Equation 5-12 showing peak area ratio(C10H8/C10D8)versus concentration ratio role="math" localid="1663559632352" ([C10H8]/C10D8) . Find the least-squares slope and intercept and their standard uncertainties. What is the theoretical value of the intercept? Is the observed value of the intercept within experimental uncertainty of the theoretical value?

(b) Find the quotientrole="math" localid="1663559638520" [C10H8]/[C10D8]for an unknown whose peak area ratio (C10H8/C10D8) is 0.652. Find the standard uncertainty for the peak area ratio.

(c) Here is why we try not to use 3-point calibration curves. For n = 3 data points, there is n - 2 = 1 degree of freedom, because 2 degrees of freedom are lost in computing the slope and intercept. Find the value of Student's for confidence and 1 degree of freedom. From the standard uncertainty in (b), compute the 95 % confidence interval for the quotient[C10H8]/[C10D8] . What is the percent relative uncertainty in the quotient[C10H8]/[C10D8]? Why do we avoid 3-point calibration curves?

Internal standard calibration curve. Figure 5-10 is a graph of Ax/Asversus[X]/[S]=(mol%vinylacetateunits)/(mol%ethyleneunits)=q/p in Reaction 5-13.

(d) From the uncertaintyubof the intercept, find the95%confidence interval for the intercept. Does this interval include the theoretical value of zero?

Chloroform is an internal standard in the determination of the pesticide DDT in a polarographic analysis in which each compound is reduced at an electrode surface. A mixture containing 0.500mMchloroform and0.800mMDDT gave signals of15.3μ´¡for chloroform and10.1μ´¡for DDT. An unknown solution(10.0mL)containing DDT was placed in a100-mLvolumetric flask and10.2μ³¢of chloroform (FM 119.39, density=1.484g/mL)were added. After dilution to the mark with solvent, polarographic signals of and8.7μ´¡were observed for the chloroform and DDT, respectively. Find the concentration of DDT in the unknown.

What is a blank and what is its purpose? Distinguish method blank, reagent blank, and field blank.

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.