/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q32P Internal standard calibration cu... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

Internal standard calibration curve. Figure 5-10 is a graph of Ax/Asversus[X]/[S]=(mol%vinylacetateunits)/(mol%ethyleneunits)=q/p in Reaction 5-13.

(d) From the uncertaintyubof the intercept, find the95%confidence interval for the intercept. Does this interval include the theoretical value of zero?

Short Answer

Expert verified

The95%confidence interval for the intercept95%confidence=±0.160

Step by step solution

01

Define the equation

We will use this equation to calculate the standard uncertainty in $x$.

ux=sym1k+1n+y-y2m2∑xi-x2

syis the standard deviation of y,

is the absolute value of the slope,

k is the number of replicate measurements of the unknown,

n is the number of data points for the calibration line,

y is the mean value of y

x is the mean value of x.

02

Obtain the 95% confidence interval.

Now, let's calculate the 95%confidence interval for XS

95%confidence=±tux95%confidence=±2.78.019495confidence=±0.541

Now again use the same formula

95%confidence=±tubub=o.o574t=2.7895confidence=±0.160

Thus confidence interval95%confidence=±0.160

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

Detection limit. A sensitive chromatographic method was developed to measure sub-part-per-billion levels of the disinfectant by-products iodate(IO3-), chlorite(CIO2-), and bromate(BrO3-)in drinking water. As the oxyhalides emerge from the column, they absorption at267nm. For example, each mole of BrO3-+8Br-+6H+R3Br3-+3H2Obromate makes by the reaction

Bromate near its detection limit gave the following chromatographic peak heights and standard deviations (s). For each concentration, estimate the detection limit. Find the mean detection limit. The blank is 0 because chromatographic peak height is measured from the baseline adjacent to the peak. Because blank =0, relative standard deviation applies to both peak height and concentration, which are proportional to each other. Detection limit is 3 s for peak height or concentration.

What is the difference between a false positive and a false negative?

Here is a use objective for a chemical analysis to be performed at a drinking water purification plant: "Data and results collected quarterly shall will be used to determine whether the concentrations of haloacetates in the treated water demonstrate compliance with the levels set by the Stage 1 Disinfection By-products Rule using Method 552.2"(a specification that sets precision, accuracy, and other requirements).

Which one of the following questions best summarizes the meaning of the use objective?

(i) Are haloacetate concentrations known within specified precision and accuracy?

(ii) Are thehaloacetates detectable in the water?

(iii) Dothehaloacetate concentrations exceed the regulatory limit?

How can you validate precision and accuracy?

Standard addition. An unknown sample of Ni2+gave a current of 2.36μ´¡in an electrochemical analysis. When 0.500mLof solution containing role="math" localid="1654761474124" 0.0187MNi2+was added to 25.0mLof unknown, the current increased to 3.79μ´¡.

(a) Denoting the initial, unknown concentration as [Ni2+], write an expression for the final concentration, [Ni2+]f, after role="math" 25.0mLof unknown were mixed with 0.500mLof standard. Use the dilution factor for this calculation.

(b) In a similar manner, write the final concentration of added standard Ni2+, designated as [S]f.

(c) Find[Ni2+]in the unknown.