/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q32P Internal standard calibration cu... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

Internal standard calibration curve. Figure 5-10 is a graph of Ax/Asversus[X]/[S]=(mol%vinylacetateunits)/(mol%ethyleneunits)=q/p in Reaction 5-13.

(d) From the uncertaintyubof the intercept, find the95%confidence interval for the intercept. Does this interval include the theoretical value of zero?

Short Answer

Expert verified

The95%confidence interval for the intercept95%confidence=±0.160

Step by step solution

01

Define the equation

We will use this equation to calculate the standard uncertainty in $x$.

ux=sym1k+1n+y-y2m2∑xi-x2

syis the standard deviation of y,

is the absolute value of the slope,

k is the number of replicate measurements of the unknown,

n is the number of data points for the calibration line,

y is the mean value of y

x is the mean value of x.

02

Obtain the 95% confidence interval.

Now, let's calculate the 95%confidence interval for XS

95%confidence=±tux95%confidence=±2.78.019495confidence=±0.541

Now again use the same formula

95%confidence=±tubub=o.o574t=2.7895confidence=±0.160

Thus confidence interval95%confidence=±0.160

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

Chloroform is an internal standard in the determination of the pesticide DDT in a polarographic analysis in which each compound is reduced at an electrode surface. A mixture containing 0.500mMchloroform and0.800mMDDT gave signals of15.3μ´¡for chloroform and10.1μ´¡for DDT. An unknown solution(10.0mL)containing DDT was placed in a100-mLvolumetric flask and10.2μ³¢of chloroform (FM 119.39, density=1.484g/mL)were added. After dilution to the mark with solvent, polarographic signals of and8.7μ´¡were observed for the chloroform and DDT, respectively. Find the concentration of DDT in the unknown.

Blind Samples: Interpreting Statistics-- The U.S. Department of Agriculture provided homogenized beef baby food samples to three labs for analysis.4Results from the labs agreed well for protein, fat, zinc, riboflavin, and palmitic acid. Results for iron were questionable: Lab A, 1.59±0.14(13); Lab B, 1.65±0.56 (8); Lab C, 2.68±0.78(3) mg/100 g . Uncertainty is the standard deviation, with the number of replicate analyses in parentheses. Use two separate t tests to compare results from Lab Cwith those from Lab A and Lab B at the 95 % confidence level. Comment on the sensibility of the t test results and offer your own conclusions.

Control chart. A laboratory monitoring perchlorate (CIO-4)in urine measured quality control samples made from synthetic urine spiked withCIO-4. The graph in Box5-2shows consecutive quality control measurements. Are any troubleshooting conditions from Box 5-2 observed in these data?

Here is a use objective for a chemical analysis to be performed at a drinking water purification plant: "Data and results collected quarterly shall will be used to determine whether the concentrations of haloacetates in the treated water demonstrate compliance with the levels set by the Stage 1 Disinfection By-products Rule using Method 552.2"(a specification that sets precision, accuracy, and other requirements).

Which one of the following questions best summarizes the meaning of the use objective?

(i) Are haloacetate concentrations known within specified precision and accuracy?

(ii) Are thehaloacetates detectable in the water?

(iii) Dothehaloacetate concentrations exceed the regulatory limit?

What is the difference between an instrument detection limit and a method detection limit? What is the difference between robustness and intermediate precision?

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.