Chapter 28: Q4TY (page 776)
How many 2.8-g samples must be analyzed to give 95% confidence that the mean is known to within ±4%?
Short Answer
6 no. of 2.8-g samples must be analyzed to give 95% confidence and the mean is known to within ±4.
/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none}
Learning Materials
Features
Discover
Chapter 28: Q4TY (page 776)
How many 2.8-g samples must be analyzed to give 95% confidence that the mean is known to within ±4%?
6 no. of 2.8-g samples must be analyzed to give 95% confidence and the mean is known to within ±4.
All the tools & learning materials you need for study success - in one app.
Get started for free
Acid-base equilibria of Cr(III) were summarized in Problem 10-36. Cr(VI) in aqueous solution above pH 6 exists as the yellow tetrahedral chromate ion, \({\rm{CrO}}_4^{2 - }.\)Between\({\rm{pH}}2\)and \(6,{\rm{Cr}}\)(VI) exists as an equilibrium mixture of\({\rm{HCrO}}_4^ - \) and orange-red dichromate,\({\rm{C}}{{\rm{r}}_2}{\rm{O}}_7^{2 - }.{\rm{Cr}}({\rm{VI}})\) is a carcinogen, but \({\rm{Cr }}(III)\)is not considered to be as harmful. The following procedure was used to measure\({\rm{Cr }}({\rm{VI}})\) in airborne particulate matter in workplaces.
1. Particles were collected by drawing a known volume of air through a polyvinyl chloride filter with \(5 - \mu {\rm{M}}\)pore size.
2. The filter was placed in a centrifuge tube and \(10\;{\rm{mL}}\)of \(0.05{\rm{M}}{\left( {{\rm{N}}{{\rm{H}}_4}} \right)_2}{\rm{S}}{{\rm{O}}_4}/0.05{\rm{MN}}{{\rm{H}}_3}buffer,{\rm{pH}}8,\) were added. The immersed filter was agitated by ultrasonic vibration for\(30\;{\rm{min}}\)at \({35^\circ }{\rm{C}}\)to extract all \({\rm{Cr }}(III)and{\rm{Cr}}\)(VI) into solution.
3. A measured volume of extract was passed through a "strongly basic" anion exchanger (Table 26-1) in the \({\rm{C}}{{\rm{l}}^ - }\)form. Then the resin was washed with distilled water. Liquid containing \({\rm{Cr}}\)(III) from the extract and the wash was discarded.
4. Cr(VI) was then eluted from the column with\(0.5{\rm{M}}{\left( {{\rm{N}}{{\rm{H}}_4}} \right)_2}{\rm{S}}{{\rm{O}}_4}/0.05{\rm{MN}}{{\rm{H}}_3}\) buffer, \({\rm{pH}}8,\)and collected in a vial.
5. The eluted \({\rm{Cr}}\)(VI) solution was acidified with \({\rm{HCl}}\)and treated with a solution of 1,5 -diphenylcarbazide, a reagent that forms a colored complex with Cr(VI). The concentration of the complex was measured by its visible absorbance.
(a) What are the dominant species of \({\rm{Cr}}\)(VI) and \({\rm{Cr}}\)(III) at\({\rm{pH}}8\)?
(b) What is the purpose of the anion exchanger in step 3 ?
(c) Why is a "strongly basic" anion exchanger used instead of a "weakly basic" exchanger?
(d) Why is Cr(VI) eluted in step 4 but not step 3 ?
Barbital can be isolated from urine by solid-phase extraction with\({{\bf{C}}_{18}} - \)silica. The barbital is then eluted with\({\bf{1}}:{\bf{1}}\) vol/volacetone: chloroform. Explain how this procedure works.

Why is it advantageous to use large particles \(\left( {{\bf{50}}{\rm{ }}\mu {\bf{m}}} \right)\) for solid phase extraction, but small particles \(\left( {{\bf{5}}{\rm{ }}\mu {\bf{m}}} \right)\) for chromatography?
In analyzing a lot with random sample variation, you find a sampling standard deviation of \({\bf{65}}\% .\)Assuming negligible error in the analytical procedure, how many samples must be analyzed to give \(9{\bf{5}}\% \)confidence that the error in the mean is within\(64\% \)of the true value? Answer the same question for a confidence level of \(90\% \).
If 105 particles are taken, what is the relative standard deviation of each measurement?
What do you think about this solution?
We value your feedback to improve our textbook solutions.