/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q58PE Calculate the emfxof a dry cell... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

Calculate theemfxof a dry cell for which a potentiometer is balanced whenRx=1.200Ω, while an alkaline standard cell with an emf 1.600Vof requiresto Rs=1.247Ωbalance the potentiometer.

Short Answer

Expert verified

The of a dry cell being for which a potentiometer is balanced is Ex=1.540V.

Step by step solution

01

Concept Introduction

The electric potential generated by an electrochemical cell or a changing magnetic field is known as electromotive force. Electromotive force (EMF) is a well-known abbreviation.

02

Information Provided

  • Emf of a standard cell:Es=1.600V
  • Resistance of the potentiometer:Rx=1.200Ω
  • Standard resistance value:Rs=1.247Ω
03

Calculation for EMF of the cell

Calculate of a cell using a potentiometer. The formula is -

Ex=EsRxRs=(1.600V)1.200Ω1.247Ω=1.600V×0.96=1.540V

Therefore, the value for emf is Ex=1.540V.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

When making an ECG measurement, it is important to measure voltage variations over small time intervals. The time is limited by the \(RC\) constant of the circuit-it is not possible to measure time variations shorter than \(RC\). How would you manipulate \(R\) and \(C\) in the circuit to allow necessary measurements?

When an unknown resistanceRxis placed in a Wheatstone bridge, it is possible to balance the bridge by adjusting R3to be 2500Ω. What is RxifR2R1=0.625?

An ECG monitor must have an \(RC\) time constant less than \(1.00 \times {10^2}{\rm{ }}\mu s\) to be able to measure variations in voltage over small time intervals. (a) If the resistance of the circuit (due mostly to that of the patient’s chest) is\(1.00{\rm{ }}k\Omega \), what is the maximum capacitance of the circuit? (b) Would it be difficult in practice to limit the capacitance to less than the value found in (a)?

Some light bulbs have three power settings (not including zero), obtained from multiple filaments that are individually switched and wired in parallel. What is the minimum number of filaments needed for three power settings?

A \(160 - \mu F\)capacitor charged to \(450\;V\)is discharged through a \(31.2 - k\Omega \)resistor. (a) Find the time constant.(b) Calculate the temperature increase of the resistor, given that its mass is \(2.50\;g\)and its specific heat is \(1.67\frac{{kJ}}{{kg{ \cdot ^\circ }C}}\), noting that most of the thermal energy is retained in the short time of the discharge. (c) Calculate the new resistance, assuming it is pure carbon. (d) Does this change in resistance seem significant?

See all solutions

Recommended explanations on Physics Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.