/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q9P Consider a sample that contains ... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

Consider a sample that contains analyte at the detection limit defined in Figure. Explain the following statements: There is approximately a 1%chance of falsely concluding that a sample containing no analyte contains analyte above the detection limit. There is a50%chance of concluding that a sample that really contains analyte at the detection limit does not contain analyte above the detection limit.

Short Answer

Expert verified

The following statements was explained.

1. Above the detection limit approximately

1%

chance of falsely concluding that the sample does contain no analyte.

2. Above the detection limit approximately50%chance of concluding that the sample doesn't contains analyte.

Step by step solution

01

The detection limit

The concentration of an analyte that produces a signal with a standard deviation three times that of a blank signal.

The minimum detectable concentration =3sm

Where,

S=Standard deviation.

m=Slope of linear calibration curve.

02

Explanation of statements

The first statement means that since there is approximately 1%chance of false negative results showing up, there will also be approximately 1%of samples (that do NOT contain the analytes) that will respond with a signal above the detection limit.

For the second statement -- which is a hypothetical situation for false positive results -- means that50% of the samples containing the analyte with a signal going below the limit of detection.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

A solution containing3.47mMX(analyte) and1.72mMS(standard) gave peak areas of3473and 10222,respectively, in a chromatographic analysis. Then1.00mLof 8.47mMSwas added to5.00mLof unknownX,and the mixture was diluted to10.00mL. This solution gave peak areas of5428and4431forXandS, respectively.

(a) Calculate the response factor for the analyte.

(b) Find the concentration of S(mM)inthe10.0-mLmixture.

(c) Find the concentration of X(mM)inthe10.0-mLmixture.

(d) Find the concentration ofXintheorignalunknown.

Europium is a lanthanide element found at parts per billion levels in natural waters. It can be measured from the intensity of orange light emitted when a solution is illuminated with ultraviolet radiation. Certain organic compounds that bindEu(III)are required to enhance the emission. The figure shows standard addition experiments in which10.00mLof sample and20.00mLcontaining a large excess of organic additive were placed in 50-mL volumetric flasks. Then Eu(III) standards (0,5.00,10.00,or15.00mL) were added and the flasks were diluted to50.0mLwithH2O. Standards added to tap water contained0.152ng/mL(ppb) of Eu(III), but those added to pond water were 100 times more concentrated (15.2 ng/mL).


(a) Calculate the concentration of Eu(III)(ng/mL) in pond water and tap water.

(b) For tap water, emission peak area increases by.4.61units when 10.00mL of 0.152ng/mL standard are added. This response is4.61 units/1.52ng = 3.03units per ng ofEu(III). For pond water, the response is12.5units when10.00mLof15.2ng/mLstandard are added, or0.0822units per ng. How would you explain these observations? Why was standard addition necessary for this analysis?

Detection limit. In spectrophotometry, we measure the concentration of an analyte by its absorbance of light. A low-concentration sample was prepared and nine replicate measurements gave absorbances of 0.0047,0.0054,0.0062,0.0060,0.0046,0.0056,0.0052,0.0044, and 0.0058. Nine reagent blanks gave values of 0.0006,0.0012, 0.0022,0.0005,0.0016,0.0008,0.0017,0.0010, and 0.0011.

a) Find the absorbance detection limit with equation 5-3.

b) The calibration curve is a graph of absorbance versus concentration. Absorbance is a dimensionless quantity. The slope of the calibration curve is m=2.24x104M-1Find the concentration detection limit with Equation 5-5.

(c) Find the lower limit of quantitation with Equation 5-6.

Blind Samples: Interpreting Statistics-- The U.S. Department of Agriculture provided homogenized beef baby food samples to three labs for analysis.4Results from the labs agreed well for protein, fat, zinc, riboflavin, and palmitic acid. Results for iron were questionable: Lab A, 1.59±0.14(13); Lab B, 1.65±0.56 (8); Lab C, 2.68±0.78(3) mg/100 g . Uncertainty is the standard deviation, with the number of replicate analyses in parentheses. Use two separate t tests to compare results from Lab Cwith those from Lab A and Lab B at the 95 % confidence level. Comment on the sensibility of the t test results and offer your own conclusions.

Standard addition graph. Students performed an experiment like that in Figure 5-7 in which each flask contained 25.00mLof serum, varying additions of 2.640MNaCIstandard, and a total volume of 50.00mL.


(a) Prepare a standard addition graph and find [Na+]in the serum.

(b) Find the standard deviation and 95%confidence interval for [Na+].

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.