/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q8P To which kinds of analyses do th... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

To which kinds of analyses do the following gas chromatography detectors respond?

(a) thermal conductivity

(b) flame ionization

(c) electron capture

(d) flame photometric

(e) nitrogen-phosphorus

(f) photo ionization

(g) sulfur chemiluminescence

(h) atomic emission

(i) mass spectrometer

(j) vacuum ultraviolet

Short Answer

Expert verified

(a.) Thermal conductivity detectors are simple and universal, which means that they react to all analyses. This makes these detectors to be frequently used in gas chromatography in the past. The thermal conductivity of the carrier gas must be completely different from the analyses, for thermal conductivity detection to proceed.

(b.)CH+O→CHO++e-

(c.) Electron capture detectors respond to halogen-containing molecules, conjugated carbonyls, nitrites, nitro compounds, and organ metallic compounds

(d.) Flame photometric detectors can control optical emission from phosphorus, sulfur, lead, tin, or other elements. The excited electrons of these elements emit characteristic light when the elute passes through a H2-air flame

(e.) Nitrogen-phosphorus detector (or alkali flame detector) is a type of flame ionization detector that is modified in such a way that it is sensitive to and -including compounds. It responds 104-106timesgreater to N and P than to carbon. Its applications include drug, pesticide, and herbicide analyses.

(f.) It has relatively low sensitivity to saturated hydrocarbons or halocarbons. The electrons produced by the ionization are collected and calculated.

(g) The intensity of the emission is proportional to the Mass of sulfur eluted and the detector responds107 times greater to S than to C.

(h) An atomic emission detector detects the characteristic emission of elements through a photodiode array polychromatic. Its sensitivity for sulfur is up to 10 times greater than the sensitiveness of flame photometric detection.

(i) Mass spectrometers are sensitive to most analytes. It can detect chromatographic peak by comparing its spectrum with a library of spectra.

(j) A vacuum ultraviolet absorbance can detect most analytes, with a detection limit of 15-250 pg.

Step by step solution

01

thermal conductivity

(a)

Thermal conductivity detectors are simple and universal, which means that they respond to all analyses. This makes these detectors are frequently used in gas chromatography in the past. The thermal conductivity of the carrier gas must be completely different from the analyses, for thermal conductivity detection to proceed. The most frequently used carrier gas is helium because it has the second highest thermal conductivity next toH2 , thus the conductivity of the gas stream is reduced with any analyte mixed with H2.

02

Step 2: flame ionization

(b)

Flame ionization detectors respond to most hydrocarbons with near constant response per carbon atom , but with lesser response for C bonded N to O . Flame ionization does not respond to no hydrocarbons such asH2,He,N2,O2,CO,CO2,H2O,NH3,NO,H2SandSiF4 . When this detector operates, the elute is burned in a mixture of H2 and air. The carbon atoms create CH radicals which are then converted toCHO+ ions and electrons in the flame, as shown in the reaction below:

CH+O→CHO++e-

03

electron capture

(c).

Electron capture detectors respond to halogen-containing molecules, conjugated carbonyls, nitrites, nitro compounds, and organ metallic compounds. However, they are relatively insensitive to hydrocarbons, alcohols, and ketoses. These detectors are applied to chlorinated pesticides and fluorocarbons in environmental samples.

04

Step 4: flame photometric

(d).

Flame photometric detectors can measure optical emission from phosphorus, sulfur, lead, tin, or other elements. The excited electrons of these elements emit characteristic light when the elute passes through a H2 -air flame. The emission of phosphorus at 526nm or sulfur at 394nm is isolated by a narrow-band interference filter and detected with a photomultiplier tube. The detector responds 105 times greater to sulfur and phosphorus compounds than to hydrocarbons. This enables the recognition of trace sulfur compounds that contribute to the aroma of beer.

05

Step 5: nitrogen-phosphorus

(e).

Nitrogen-phosphorus detector (or alkali flame detector) is a type of flame ionization detector that is modified to become sensitive to N and P -containing compounds. It responds 104-106times greater to N and P than to carbon. Its applications include drug, pesticide, and herbicide analyses.

06

Step 6: photo ionization

(f)

A photo ionization detector ionizes aromatic and unsaturated compounds by employing a vacuum ultraviolet source. It has relatively low sensitivity to saturated hydrocarbons or halocarbons. The electrons produced by the ionization are collected and measured.

07

Step 7: sulfur chemiluminescence

(g).

A sulfur chemiluminescence detector analyzes the exhaust from a flame ionization detector, wherein sulfur is oxidized toSO, and mixes it with ozoneO3to form an excited state of SO2 that emits blue and ultraviolet radiation. The intensity of the emission is proportional to the Mass of sulfur eluted and the detector responds times greater to S than to C.

08

Step 8: atomic emissionatomic emission

(h).

An atomic emission detector detects the characteristic emission of elements thru a photodiode array polychromatic. Its sensitivity for sulfur is up to 10 times greater than the sensitivity of flame photometric detection.

09

Step 9: mass spectrometer

(i).

Mass spectrometers are sensitive to most analytes. It can identify a chromatographic peak by comparing its spectrum with a library of spectra.

10

vacuum ultraviolet

(J).

A vacuum ultraviolet absorbance can detect most analytes, with a detection limit of 15-250 pg.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

Consider the chromatography of n-c12H26on a 25 m × 0.53 mm open tubular column of 5% phenyl–95% methyl polysiloxane with a stationary phase thickness of 3.0 μ³¾and He carrier gas at 125ºC. The observed retention factor for n-c12H26is 8.0. Measurements were made of plate height, H, at various values of linear velocity,μxm/s. A least-squares curve through the data points is given by

localid="1654864230381" H(m)=(6.0×10-5m2/s)/μx+(2.09×10-3s)μxthecoefficientsofthevanDeemterequation,findthediffusioncoefficientofn-c12H26inthemobileandstationaryphases.Whyisoneofthesediffusioncoefficientssomuchgreaterthantheother?

Use Table 24-2 to predict the elution order of the following compounds from columns containing (a) poly (dimethyl siloxane), (b) (diphenyl)0.35(dimethyl)0.65polysiloxane, and (c) poly (ethylene glycol): hexane, heptane, octane, benzene, butanol, 2-pentanone.

The gasoline additive methyl t-butyl ether (MTBE) has been leaking into groundwater ever since its introduction in the. MTBE can be measured at parts per billion levels by solid-phase microextraction from groundwater to which 25 % (wt/vol) NaCl has been added (salting out, Problem 8-9). After microextraction, analytes are thermally desorbed from the fiber in the port of a gas chromatograph. The figure on the next page shows a reconstructed total ion chromatogram and selected ion monitoring of substances desorbed from the extraction fiber.

(a) What is the purpose of adding NaCl prior to extraction?

(b) What nominal mass is being observed in selected ion monitoring? Why are only three peaks observed?

(c) Here is a list of major ions above m/z50 in the mass spectra. The base (tallest) peak is marked by an asterisk. Given that MTBE and TAME have an intense peak at m/z,73 and there is no significant peak at m/z,73 for ETBE, suggest a structure for m/z,73. Suggest structures for all ions listed in the table.

The graph shows van Deemter curves for n-nonane at . in the 3.0-m-long microfabricated column in Box 24-2 with a -thick stationary phase.

van Deemter curves. [Data from G. Lambertus, A. Elstro, K. Sensenig, J. Potkay, M. Agah, S. Scheuening, K. Wise, F. Dorman, and R. Sacks, "Design, Fabrication, and Evaluation of Microfabricated Columns for Gas Chromatography," Anal. Chem. 2004, 76, 2629.]

(a) Why would air be chosen as the carrier gas? What is the danger of using

air as carrier gas?

(b) Measure the optimum velocity and plate height for air and for carrier

gases.

(c) How many plates are there in the 3 -m-long column for each carrier gas at

optimum flow rate?

(d) How long does unretained gas take to travel through the column at

optimum velocity for each carrier gas?

(e) If stationary phase is sufficiently thin with respect to column diameter, which of the two mass transfer terms (23-40 or 23-41) becomes negligible?

Why?

(f) Why is the loss of column efficiency at high flow rates less severe for

than for air carrier gas?

Here is a student procedure to measure nicotine in urine. A 1.00-mL sample of biological fluid was placed in a 12-mL vial containing 0.7gNa2CO3powder. After 5.00μ²µof the internal standard 5 -aminoquinoline were injected, the vial was capped with a Teflon coated silicone rubber septum. The vial was heated to 80°cfor 20 min and then a solid-phase microextraction needle was passed through the septum and left in the headspace for 5.00min. The fiber was retracted and inserted into a gas chromatograph. Volatile substances were desorbed from the fiber at 250°cfor 9.5min in the injection port while the column was at 60°c. The column temperature was then raised to 250°cat 25°c/minand eluate was monitored by electron ionization mass spectrometry with selected ion monitoring at m/z 84 for nicotine and m / z 144 for internal standard. Calibration data from replicate standard mixtures taken through the same procedure are given in the table.

(a) Why was the vial heated to 80°cbefore and during extraction?

(b) Why was the chromatography column kept at 60°Cduring thermal desorption of the extraction fiber?

(c) Suggest a structure for m / z 84 from nicotine. What is the m / z, 144 ion from the internal standard, 5 -aminoquinoline?

(d) Urine from an adult female nonsmoker had an area ratio m / z .84 / 144=0.51 and 0.53 in replicate determinations. Urine from a nonsmoking girl whose parents are heavy smokers had an area ratio 1.18 and 1.32.

Find the nicotine concentration (μ²µ/L)and its standard uncertainty in the urine of each person.

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.