/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q6P Propose a scheme for separating ... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

Propose a scheme for separating trimethylamine, dimethylamine, methylamine, and ammonia from one another by ion-exchange chromatography.

Short Answer

Expert verified

Principle of ion-exchange chromatography:Molecules are separated because of difference in their charges and are eluted with a solution which has a varying ionic strength. When that kind of solution passes through the column the molecules are highly separated according to their different charges.

Step by step solution

01

Order of separation of molecules

Molecules will be separated in the following order:

Ammonia < trimethylamine < methylamine < dimethylamine due topKa their values.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

Figure 26-24 shows the effect on resolution of increasing voltage from 28 to120kV

(a) What is the expected ratio of migration times(t120kV/t28kV)in the two experiments? Measure the migration times for peak 1 and find the observed ratio.

(b) What is the expected ratio of plates (N120kv/N28kv)in the two experiments?

(c) What is the expected ratio of bandwidths(σ120kv/σ28kv)?

(d) What is the physical reason why increasing voltage decreases bandwidth and increases resolution?

A gel filtration column has a radius, y.of 0.80 cm and a length,l, of 20.0 cm

(a).Calculate the volume,Vtof the column, which is equal toÏ€°ù2

(b). The interstitial volumeV0was 18.1 mL and the total volume of mobile phase was 35.8 mL.

Find.Kavfor a solute eluted at 27.4 mL.

Ferritin (molecular mass 450 000), transferrin (molecular mass 80 000), and ferric citrate were separated by molecular exclusion chromatography on Bio-Gel P-300. The column had a length of 37 cm and a 1.5-cm diameter. Eluate fractions of 0.65 mL were collected. The maximum of each peak came at the following fractions: ferritin, 22; transferrin, 32; and ferric citrate, 84. (That is, the ferritin peak came at an elution volume of 22 3 0.65 5 14.3 mL)Assuming that ferritin is eluted at the interstitial volume and that ferric citrate is eluted at Vm, findKavfor transferrin.

Figure 26-23 shows the separation of substituted benzoates. There is a peak of unknown identity at 86.0 seconds. (a) Is the unknown a cation, neutral, or an anion? (b) Find the apparent mobility and electrophoretic mobility of the unknown peak.

What is electroosmosis?

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.