/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q47P When the following three compoun... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

When the following three compounds are separated by micellar electrokinetic chromatography at, three peaks are observed. When 10mMvα-cyclodextrinis added to the run buffer, two of the three peaks split into two peaks, giving a total of five peaks. Explain this observation and predict which compound does not split.

Short Answer

Expert verified

Cyclobarbital and Thiopental will generate two peaks whereas phenobarbital would have one peak.

Step by step solution

01

Definition of electrokinetic chromatography

Micellar electrokinetic chromatography (MEKC) is a chromatography technique used in analytical chemistry. It used for separating neutral molecules and ions.

02

Explanation of observation

Among the three compounds, cyclobarbital and thiopental have one chiral carbon, whereas phenobarbital is achiral. Both cyclobarbital and thiopental form non-superimposable mirror images known as enantiomers.

The enantiomers will spend different time interacting with cyclodextrin as they migrate through the capillary. This will lead to splitting of the peaks cyclobarbital and thiopental into two separate peaks resulting in a total of five peaks. The chiral centres for cyclobarbital and thiopental are marked with an asterisk.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

(a) State the purpose of the separator and suppressor in suppressed ion chromatography. For cation chromatography, why is the suppressor an anion-exchange membrane?

The observed behavior of benzyl alcohol (C6H5CH2OH) in capillary electrophoresis is given here. Draw a graph showing the number of plates versus the electric field and explain what happens as the field increases.

Injection in some homebuilt capillary electrophoresis instruments is performed by raising the sample vial to create a siphon. The pressure exerted by a column of water of heightiswhereis the density of water and gis the acceleration of gravity (9.8m/s2). To what height would you need to raise the sample vial to create the necessary pressure to load the sample in 4.0 s? Is it possible to raise the inlet of this column to this height? How could you obtain the desired pressure?

A gel filtration column has a radius, y.of 0.80 cm and a length,l, of 20.0 cm

(a).Calculate the volume,Vtof the column, which is equal toÏ€°ù2

(b). The interstitial volumeV0was 18.1 mL and the total volume of mobile phase was 35.8 mL.

Find.Kavfor a solute eluted at 27.4 mL.

Decomposition of dithionite(S2O42-).was studied by chromatography on an anion-exchange column eluted with 20mM tri-sodium 1, 3, 6-napthalenetrisulfonate in 90 vol%H2O/10

vol%CH3CNwith ultraviolet detection at 280 nm. A solution of sodium dithionite stored for 34 days in the absence of air gave five peaks identified asSO32-,SO42-,S2O32-,S2O42-andS2Os2-All the peaks had a negative absorbance. Explain why.

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.