/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Q31P (a) Explain the purpose of the d... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

(a) Explain the purpose of the dynamic reaction cell in Figure 21-30. (b) In geologic strontium isotopic analysis, there is isobaric interference between87Rb+and87Sr+ . A dynamic reaction cell with CH3Fconverts to but does not convertRb+ toRbF+ . How does this reaction eliminate interference?

Short Answer

Expert verified

(a) A dynamic reaction cell reduces isobaric interference by performing a thermodynamically favourable reaction with a gas such as NH3,N2Oor COto remove interfering molecular ions like ArO+.

(b) When S87r+ reacts with CH3Fto generate S87rF19e, which has a mass of 106 , the mass spectrum does not overlap with R87b.

Step by step solution

01

Define isotopic interference.

Isotopic interference occurs when two isotopes in a sample solution have the same mass but are from different elements.

02

Explain the elimination of the interference in the given reaction.

(a)

A dynamic reaction cell reduces isobaric interference by performing a thermodynamically favourable reaction with a gas such as NH3,N2Oor COto remove interfering molecular ions like ArO+or convert analyte into a molecular ion that can be detected without interference.

(b)

When S87r+reacts with CH3Fto generate S87rF19e, which has a mass of 106 , the mass spectrum does not overlap with .

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

What is the purpose of a matrix-matched standard in laser-induced breakdown spectroscopy?

Concentrations (pg per g of snow) of metals by atomic fluorescence in the Agassiz Ice Cap in Greenland for the period 1988 - 1992are 38Pb,1.04(±0.17)×102;Tl,0.43±0.087;Cd,3.5±0.87;Zn,1.74(±0.26)×102;and Al,6-1(±1-7)×103. The mean annual snowfall was . Calculate the mean annual flux of each metal in units of . Flux means how much metal falls on each .

Bone consists of the protein collagen and the mineral hydroxyapatite, Ca10(PO4)(OH)2. The content of archaeological human skeletons measured by graphite furnace atomic absorption sheds light on customs and economic status of individuals in historical times. 37Explain whyLa3+is added to bone samples to suppress matrix interference in Pbanalysis.

Bone consists of the protein collagen and the mineral hydroxyapatite, Ca10(PO4)6(OH)2. The content of archaeological human skeletons measured by graphite furnace atomic absorption sheds light on customs and economic status of individuals in historical times. 37Explain why La3+is added to bone samples to suppress matrix interference inanalysis.

Mn was used as an internal standard for measuring Fe by atomic absorption. A standard mixture containing 2.00μ²µ²Ñ²Ô/mLand2.50μ²µ¹ó±ð/mLgave a quotient (Fe signal/Mn signal) = 1.05 / 1.00. A mixture with a volume of 6.00 mLwas prepared by mixing 5.00 mLof unknown Fe solution with 1.00mLcontaining13.5μ²µ²Ñ²Ô/mL. The absorbance of this mixture at the Mn wavelength was 0.128, and the absorbance at the Fe wavelength was 0.185. Find the molarity of the unknown Fe solution.