/*! This file is auto-generated */ .wp-block-button__link{color:#fff;background-color:#32373c;border-radius:9999px;box-shadow:none;text-decoration:none;padding:calc(.667em + 2px) calc(1.333em + 2px);font-size:1.125em}.wp-block-file__button{background:#32373c;color:#fff;text-decoration:none} Problem 31 A coal-fired electrical generati... [FREE SOLUTION] | 91Ó°ÊÓ

91Ó°ÊÓ

A coal-fired electrical generating station can use a higher \(T_{\mathrm{H}}\) than a nuclear plant; for safety reasons the core of a nuclear reactor is not allowed to get as hot as coal. Suppose that $T_{\mathrm{H}}=727^{\circ} \mathrm{C}\( for a coal station but \)T_{\mathrm{H}}=527^{\circ} \mathrm{C}$ for a nuclear station. Both power plants exhaust waste heat into a lake at \(T_{\mathrm{C}}=27^{\circ} \mathrm{C} .\) How much waste heat does each plant exhaust into the lake to produce \(1.00 \mathrm{MJ}\) of electricity? Assume both operate as reversible engines.

Short Answer

Expert verified
The coal-fired power plant exhausts 0.429 MJ of waste heat, and the nuclear power plant exhausts 0.6 MJ of waste heat into the lake to produce 1.00 MJ of electricity.

Step by step solution

01

Convert Celsius to Kelvin

First, we need to convert the given temperatures from degrees Celsius to Kelvin. To do this, we add 273 to the Celsius temperature. So, \(T_{\mathrm{H}}(coal) = 727 + 273 = 1000\mathrm{K}\) and \(T_{\mathrm{H}}(nuclear) = 527 + 273 = 800\mathrm{K}\). Similarly, \(T_{\mathrm{C}} = 27 + 273 = 300\mathrm{K}\).
02

Calculate the efficiency of both coal and nuclear power plants

Now, we need to find the efficiency of both power plants. Since the power plants are assumed to be reversible, we use the Carnot efficiency formula: Efficiency = \(1 - \frac{T_{\mathrm{C}}}{T_{\mathrm{H}}}\). For coal: Efficiency = \(1 - \frac{300\mathrm{K}}{1000\mathrm{K}} = 0.7\). For nuclear: Efficiency = \(1 - \frac{300\mathrm{K}}{800\mathrm{K}} = 0.625\).
03

Calculate the input heat for both power plants

We are given the amount of electricity produced by both power plants, which can be considered as their useful work output. Their efficiency multiplied by the heat input equals the useful work output. Therefore, the heat input can be found by dividing the useful work output (1.00 MJ) by the calculated efficiencies. For coal: \(Q_{\mathrm{in}}(coal) = \frac{1.00\mathrm{MJ}}{0.7} ≈ 1.43\mathrm{MJ}\). For nuclear: \(Q_{\mathrm{in}}(nuclear) = \frac{1.00\mathrm{MJ}}{0.625} ≈ 1.6\mathrm{MJ}\).
04

Calculate the waste heat for both coal and nuclear power plants

Finally, we can calculate the waste heat exhausted by both power plants using the input heat and their respective efficiencies. The waste heat equals \((1-\text{efficiency})\times Q_{\mathrm{in}}\). For coal: Waste heat = \((1-0.7) \times 1.43\mathrm{MJ} = 0.3 \times 1.43\mathrm{MJ} = 0.429\mathrm{MJ}\), and for nuclear: Waste heat = \((1-0.625) \times 1.6\mathrm{MJ} = 0.375 \times 1.6\mathrm{MJ} = 0.6\mathrm{MJ}\). So, the coal-fired power plant exhausts 0.429 MJ of waste heat, and the nuclear power plant exhausts 0.6 MJ of waste heat into the lake to produce 1.00 MJ of electricity.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with 91Ó°ÊÓ!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

A heat pump is used to heat a house with an interior temperature of \(20.0^{\circ} \mathrm{C} .\) On a chilly day with an outdoor temperature of \(-10.0^{\circ} \mathrm{C},\) what is the minimum work that the pump requires in order to deliver \(1.0 \mathrm{kJ}\) of heat to the house?
The motor that drives a reversible refrigerator produces \(148 \mathrm{W}\) of useful power. The hot and cold temperatures of the heat reservoirs are \(20.0^{\circ} \mathrm{C}\) and \(-5.0^{\circ} \mathrm{C} .\) What is the maximum amount of ice it can produce in \(2.0 \mathrm{h}\) from water that is initially at \(8.0^{\circ} \mathrm{C} ?\)
A container holding \(1.20 \mathrm{kg}\) of water at \(20.0^{\circ} \mathrm{C}\) is placed in a freezer that is kept at \(-20.0^{\circ} \mathrm{C} .\) The water freezes and comes to thermal equilibrium with the interior of the freezer. What is the minimum amount of electrical energy required by the freezer to do this if it operates between reservoirs at temperatures of $20.0^{\circ} \mathrm{C}\( and \)-20.0^{\circ} \mathrm{C} ?$
A balloon contains \(200.0 \mathrm{L}\) of nitrogen gas at $20.0^{\circ} \mathrm{C}$ and at atmospheric pressure. How much energy must be added to raise the temperature of the nitrogen to \(40.0^{\circ} \mathrm{C}\) while allowing the balloon to expand at atmospheric pressure?
An electric power station generates steam at \(500.0^{\circ} \mathrm{C}\) and condenses it with river water at \(27^{\circ} \mathrm{C} .\) By how much would its theoretical maximum efficiency decrease if it had to switch to cooling towers that condense the steam at \(47^{\circ} \mathrm{C} ?\)
See all solutions